20
GAS PIPE PRESSURE 
TESTING
The appliance must be isolated from the gas 
supply piping system by closing its individual 
manual shut-off valve during any pressure 
testing of the gas supply piping system at 
test pressures equal to or less than 1/2 psig. 
(3.45 kPa).  Disconnect piping from valve at 
pressures over 3.45 kPa.
The manifold pressure is controlled by a 
regulator built into the gas control, and should 
be checked at the pressure test point.
Note: To properly check gas pressure, both 
inlet and manifold pressures should 
be checked using the valve pressure 
ports on the valve.
1)  Make sure the valve is in the "OFF" 
position.
2)  Loosen the "IN" and/or "OUT" pressure 
tap(s), turning counterclockwise with a 
 
1/8" wide fl at screwdriver.
3)  Attach manometer to "IN" and/or "OUT" 
pressure tap(s) using a 5/16" ID hose.
P36-NG System Data 
For 0 to 4500 feet altitude
Burner Inlet Orifi ce Sizes: #37( 2.65mm)
 
 
                  
Max. Input Rating  33 
mj
Min. Input Rating 
20 mj
 
 
Supply Pressure min.1.25 
kPa
 
 
 
Manifold Pressure  
 (High)
 0.9 
kPa
 
Electrical: 240 V   A.C. System.
Circulation Fan: variable speed 130 CFM.
Log Set: Ceramic fi bre, 7 per set.
Flue System: Simpson Dura-Vent Direct
 
Flue System or Regency
®
 Direct 
 Flue 
System 
(Flex)
P36-LPG System Data 
For 0 to 2000 feet altitude
Burner Inlet Orifi ce Sizes: #52 (1.6 mm) 
 
                  
Max. Input Rating 
31 mj
Min. Input Rating 
18 mj
For 0 to 4500 feet Altitude:
Supply Pressure min 
2.75 
kPa
Manifold Pressure  
 (High)
  
2.7 kPa
Electrical: 240 V   A.C. System.
Circulation Fan: variable speed 130 CFM.
Log Set: Ceramic fi bre, 7 per set.
Flue System: Simpson Dura-Vent Co Axial 
Flue System
PILOT ADJUSTMENT
Periodically check the pilot fl ames. Correct 
fl ame pattern has three strong blue fl ames: 
1 fl owing around the thermopile, 1 around 
the thermocouple and 1 fl owing across the 
burner (it does not have to be touching the 
burner).
Note:  If you have an incorrect fl ame pattern, 
contact your Regency
®
 dealer for 
further instructions.
Incorrect fl ame pattern will have small, 
probably yellow fl ames, not coming into 
proper contact with the rear burner or 
thermopile or thermocouple. 
 
AERATION 
ADJUSTMENT
The air shutter can be adjusted by moving the 
adjusting wire up or down. The wire is accessed 
through the bottom louvre opening. Open the air 
shutter for a blue fl ame or close for a yellower 
fl ame. The burner aeration is factory set but 
may need adjusting due to either the local gas 
supply or altitude. This adjustment is performed 
by the gas fi tter.
Minimum Air Shutter Opening:
 
8 mm 
      NG
 
Full Open     LPG
CAUTION: Carbon will be produced if air shutter 
is closed too much. 
Note:   Any  damage due to carboning 
resulting from improperly setting 
the aeration controls is NOT covered 
under warranty.
Closed - Tall yellow
Open - Short Blue
GAS LINE 
INSTALLATION
The gas line can be brought through either the 
right or the left side of the appliance. The gas 
valve is situated on the right hand side of the 
unit and the gas inlet is on the right hand side 
of the valve.
Note:  If the gas line is being installed from 
the left side, be sure to leave room to 
accommodate servicing of the fan.
The gas line connection may be made of 
rigid pipe, copper pipe or an approved fl ex 
connector. (If you are using rigid pipe, ensure 
that the valve can be removed for servicing.) 
Since some municipalities have additional local 
codes it is always best to consult with your local 
authorities and the AS5601-2004 or NZS 5261 
installation code.
When using copper or fl ex connectors use only 
approved fi ttings. Always provide a union so 
that gas lines can be easily disconnected for 
servicing. Flare nuts for copper lines and fl ex 
connectors are usually considered to meet this 
requirement.
Important: Always check for gas leaks with a 
soap and water solution or gas leak detector. 
Do not use open fl ame for leak testing.
INSTALLATION