Regency Wraps P36-NG4 ユーザーズマニュアル

ページ / 44
Regency
®
 P36-4 Gas Log Fireplace
30
OPERATING INSTRUCTIONS
OPERATING 
INSTRUCTIONS
1)  Read and understand these instructions 
before operating this appliance.
2)  Check to see that all wiring is correct and 
enclosed to prevent possible shock.
3)  Check to ensure there are no gas leaks.
4)  Make sure the glass in the door frame is 
properly positioned. Never operate the 
appliance with the glass removed.
5)  Verify that the flueing and cap are 
unobstructed.
6)  Ensure that the brick panels are installed.
7)  Verify log placement. If the pilot cannot be 
seen when lighting the unit, the logs have 
been incorrectly positioned.
8)  The unit should never be turned off, and on 
again without a minimum of a 60 second 
wait.
OPTIONAL 
FAN
240 Volt AC power is needed for the fan switch 
and blower. The fan can be hard wired if desired. 
A terminal block is provided on the left hand side 
of the unit. A three wire power cord can also be 
used and plugged into a suitable receptacle.
Unit must be grounded at all times. Do 
not cut the ground terminal off under any 
circumstances.
1)  Shut the power off.
2)  Open the bottom louvre door. 
3)  Remove the terminal block cover.
4)  Slide the fan in towards the rear of the unit 
and slip it over the two mounting studs. 
Ensure that the fan blades do not rub 
against the valve tubing.
 
Optional: If you require extra space to slide 
the fan to the back, the left spring can be 
unhooked from the bracket. 
5)  Wire the fan to the terminal block as shown 
in the wiring diagram below.
6)  Connect white wire from fan to neutral of 
terminal block.
7)  Slide the  thermodisc into the bracket clip 
on the underside of the fi rebox.
8)  Connect black wire from fan to the 
thermodisc.
9)  Connect fan ground cable to ground lug. 
Refer to wiring diagram.
10) Attach the ground wire to the stove (ground 
lug provided).
11)  Attach black wire from thermodisc to terminal 
block. 
12) Hard wire into terminal block and to fan 
speed controller. Wires not supplied.
Note: A 240 Volt AC power cord can be 
installed at rough-in stage so that 
the power is available. A three wire 
power cord can be used.
13) Attach the terminal block cover. If the left 
spring was unhooked in step 4), hook it back 
into the bracket.
To Remove the Fan
1)  Shut the power off.
2)  Reverse the above instructions.
Note:   The bearings are lubricated for life. 
Do not lubricate them. Make sure 
you vacuum the fan area on a regular 
basis.
IMPORTANT:
These fans collect a lot of dust from within 
your home. Ensure you maintain these fan 
motors on a regular basis by vacuuming 
out the fan blades and housing using a soft 
brush nozzle.