Heat & Glo  •  Cerona-36, Cerona-42  •  2106-900 Rev. H  •  11/08
4
B. BTU Specifi cations
Note:  This installation must conform with local codes. In the 
absence of local codes you must comply with the National 
Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and 
the CAN/CGA B149 Installation Codes in Canada.
Listing and Code Approvals 
 
MODELS:  CERONA-36, CERONA-42
LABORATORY:  Underwriters Laboratories, Inc. (UL)
TYPE:  Direct Vent Gas Appliance Heater
STANDARD: ANSI Z21.88b-2005 • CSA2.33b-M2005 • UL307B
Do NOT use this appliance if any part has been under water. 
Immediately call a qualifi ed service technician to inspect the 
appliance and to replace any part of the control system and 
any gas control which has been under water.
This product is listed to ANSI standards for “Vented Gas 
Appliance Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and 
Recreational Vehicles”, and “Gas Fired Appliances for 
Use at High Altitudes”.
A. Appliance Certifi cation
D.  Non-Combustible Materials Specifi cation
Material which will not ignite and burn. Such materials are 
those consisting entirely of steel, iron, brick, tile, concrete, 
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136, 
Standard Test Method for Behavior of Materials in a 
Vertical Tube Furnace at 750ºC, 
shall be considered 
non-combustible materials.
E.  Combustible Materials Specifi cation
Materials made of or surfaced with wood, compressed 
paper, plant fi bers, plastics, or other material that can ig-
nite and burn, whether fl ame proofed or not, or whether 
plastered or unplastered shall be considered combustible 
materials.
F. Electrical Codes
NOTICE:  This appliance must be electrically wired and 
grounded in accordance with local codes or, in the absence 
of local codes, with 
National Electric Code ANSI/NFPA 
70-latest edition 
or the Canadian Electric Code CSA 
C22.1.
•  A 110-120 VAC circuit for this product must be protected 
with ground-fault circuit-interrupter protection, in compliance 
with the applicable electrical codes, when it is installed in 
locations such as in bathrooms or near sinks.
WARNING
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.  
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance.  It should not be 
factored as primary heat in residential heating calculations.
C. High Altitude Installations
U.L. Listed gas appliances are tested and approved with-
out requiring changes for elevations from 0 to 2000 feet in 
the U.S.A. and Canada.
When installing this appliance at an elevation above 2000 
feet, it may be necessary to decrease the input rating 
by changing the existing burner orifi ce to a smaller size. 
Input rate should be reduced by 4% for each 1000 feet 
above a 2000 foot elevation in the U.S.A., or 10% for el-
evations between 2000 and 4500 feet in Canada. If the 
heating value of the gas has been reduced, these rules 
do not apply. To identify the proper orifi ce size, check with 
the local gas utility.
If installing this appliance at an elevation above 4500 feet 
(in Canada), check with local authorities.
Model
(U.S. or Canada)
Maximum
Input BTU/h
Minimum
Input BTU/h
Orifi ce 
Size  
(DMS)
Cerona-36 (NG)
US
(0-2000 FT)
37,500
25,000
32
CAN 
(2000-4500 FT)
33,750
22,300
33
Cerona-42 (NG)
US
(0-2000 FT)
48,000
32,000
29
CAN 
(2000-4500 FT)
40,500
28,800
30
This model may be installed in a bedroom or bed-sitting 
room in the U.S.A. and Canada.