Heat & Glo  •  CFX-CRESCENT  •  705-900  Rev. P  •  12/07
27
Figure 21.   Proper Positioning, Leveling, and
  Securing of a Fireplace
Step 5
The Gas Control
System
WARNING: THIS UNIT IS NOT FOR USE
WITH SOLID FUEL.
Intermittent Pilot Ignition (IPI) System
Figure 22.  Gas Control System
Step 4
Positioning,
Leveling, and
Securing the
Fireplace
!
!
WARNING: To secure proper
clearances the front framing
header must be installed on
its narrow edge and to the
front of the frame.
BOTTOM (2)
FRAMING TABS
TOP (4)
FRAMING
TABS
To properly position, level,
and secure the fireplace:
1. Place the fireplace into
position.
2. Level the fireplace from
side to side and from
front to back.
3. Fold out top four framing
tabs to be flush with (2)
bottom tabs as shown
(Figure 21).
4. Secure the fireplace to
the framing by nailing or
screwing to all six fram-
ing tabs.
NOTE: Before positioning
fireplace into framing re-
move Finishing Strips that
are secured to right side
of fireplace. The strips will
be used in the finishing
process. Refer to Finish-
ing Variations addendum
included in manual bag.
WARNING: CONTINUOUS 110-120 VAC SER-
VICE MUST BE WIRED DIRECTLY TO THE
FIREPLACE JUNCTION BOX .
The gas control system
used with this model is
Intermittent Pilot Ignition
(IPI). This system in-
cludes a 3V control valve.
electronic module, and
intermittent pilot.
Figure 20.  Remove Finishing Strips
FINISHING
STRIPS
IGNITOR