NOTE:  Maximum number of 45° elbows permitted for a 
vertical installation is eight, provided their installation does 
not decrease maximum allowable horizontal run (as specified 
by vent graph, on page 11). 
Figure 5.11  
35 ft. (11m) 
MAXIMUM
NOTE:   Maximum vertical rise allowable is 35 ft. (11m) 
Figure 5.11).  
2'
1'
2'
1'
1'
NOTE:   Maximum number of 90° elbows permitted for a 
vertical installation is four, provided the termination falls 
within the shaded area shown in vent graph on page 10. See 
also 
Figure 5.12, within the four 90° elbows configuration, 
the maximum allowable pipe length on the horizontal runs is 
1 ft. (305mm) the minimum allowable pipe length on vertical 
runs is 1 ft. (305mm).  
ADDITIONAL RESTRICTION: This installation may not 
have two horizontal sections connected by 90° elbows. 
Figure 5.12  
Step 1. 
Check the installation instructions for required 1 in. (25mm) 
clearances (air space) to combustibles when passing 
through ceilings, walls, roofs, enclosures, attic rafters, or 
other nearby combustible surfaces.  See page 16, 
Figure 
5.17.   Check the instructions below for maximum vertical rise 
of the venting system, and any maximum horizontal offset 
limitations. All offsets must fall within the set parameters of 
the vent graph (
Figure 5.2) located on page 11.
G.  Vertical Termination
1. Direct Vent Pipe
Figure 5.10  
VERTICAL
TERMINATION
CAP
STORM 
COLLAR
FLASHING
FIRESTOP
PIPE 
LENGTH
SUPPORT
BOX
Fire Risk.
Explosion Risk.
Maintain vent clearance to combustibles as speci-
fi ed.
WARNING
•  Do not pack air space with insulation or other 
materials.
Failure to keep insulation or other materials away 
from vent pipe may cause fi re.