Step 1. 
Determine the desired location of the appliance. Check to 
ensure that wall studs or roof rafters are not in the way when 
the venting system is attached. If this is the case, you may 
want to adjust the location of the appliance.
F.  Horizontal Termination
Figure 5.4
Figure 5.3   
Step 3. 
For installations using a support box/wall thimble (check 
pipe manufacturer's instructions), mark the wall for a 10 in. 
x 10 in.  (254mm x 254mm) square hole.  The center of 
the square hole should line up with the center line of the 
horizontal pipe, as shown in 
Figure 5.5, on the next page.  
Cut and frame the hole in the exterior wall where the vent will 
be terminated.  If the wall being penetrated is constructed of 
noncombustible material, i.e. masonry block or concrete, a 
7 in. (178mm) diameter hole is acceptable.  
90 DEGREE 
ELBOW
PIPE LENGTH
PIPE LENGTH
WALL 
THIMBLE 
COVER
HHW2 - 
Recommended 
for optimum 
performance.
WALL 
THIMBLE
Fire Risk.
Explosion Risk.
Combustion Fume Risk.
Use vent run supports per installation instructions.
Connect vent sections per installation instructions.
•  Maintain all clearances to combustibles.
•  Do NOT allow vent to sag below connection 
point to appliance.
 •  Maintain specifi ed slope (if required).
WARNING
Improper support may allow vent to sag or separate.
Fire Hazard.
Exhaust Fume Risk.
Impaired Performance of Appliance.
WARNING
•  Ensure vent components are locked together correctly.
•  Pipe may separate if not properly joined. 
Step 2.  
Direct vent pipe is designed with a locking connection. To 
connect the venting system to the appliance flue outlet, a 
twist-lock adapter is built into the appliance at the factory.  
Remember to include wall thickness in minimum clearances 
when figuring the measurements for your installation 
needs.
Note:  Direct vent pipe is designed to slide straight onto 
the male ends of adjacent pipes and fittings by orienting the 
pipe indentations so they match and slide into the entry slots 
on the male ends, see
 Figure 5.4.  Push the pipe sections 
completely together, then twist-lock one section clockwise 
approximately one-quarter turn, until the two sections are 
fully locked. The female locking lugs may not be visible from 
the outside, on the pipe or fittings. They may be located by 
examining the inside of the female ends.