Mount the two framing mount brackets on each side and secure the fireplace 
to framing with screws or nails (refer to Figure 7). The brackets will allow 
for a 1⁄2” (13 mm), 5⁄8” (16 mm), 3⁄4” (19 mm) thick finishing wall. The wall 
may be finished up to the fireplace facing with combustible material.
Figure 11.  Nail Tab.
Initial Installation
QUALIFIED INSTALLERS ONLY
F
RAMING
 M
OUNT
 B
RACKETS
:
C
ORNER
 I
NSTALLATION
:
The dimensions for installing a fireplace in the corner of a room are given in Figures 12 and 13. Refer to 
“I
NITIAL
 I
NSTALLATION
 - V
ENT
 C
ONFIGURATIONS
 
AND
 R
ESTRICTOR
 S
ETTINGS
” for allowable pipe lengths. 
Do not interfere with the structural integrity of the walls.
Figure 12.  Dimensions for a corner installation, rear 
vented.
13
Figure 13.  Dimensions for a corner installation, top 
vented.
R
AISED
 F
IREPLACES
 
AND
 H
EARTHS
:
Figure 15.  Raised Fireplace with Floor Level Hearth