Hearth & Home Technologies 2700-I ユーザーズマニュアル
Page 7
September 1, 2008
R
7007-161H
2700-I WOOD INSERT (ACT)
Floor
Ceiling
Caulk
Floor
(second Story)
Non-Combustible
Firestopping
Material
Minimum 1 inch (25mm)
clearance from exterior
chimney to sheathing
Firestopping
2 inch
(51mm)
CHIMNEY REqUIREMENTS
Non-combustible
fire stopping material
Minimum 2 inch (51mm) clearance
from combustible material
and insulation
ceiling
At least 2 ft
(61cm)
At least ft
(91cm)
CHIMNEY HEIGHT
10 ft
(05cm)
CHIMNEY TOp VIEW
FLUE
Foundation
1/2" (12.7mm) airspace
5/8" (16mm)
Fireclay Flue
Liner
Chimney Wall
4" (102mm)
Nominal
Figure 7.1
OVALIZING ROUND STAINLESS STEEL
LINERS
Ovalizing round stainless steel liners to accommodate the
liner passing through the damper region of a fireplace is an
allowable and acceptable practice.
Ensure that the ovalization is minimized to the extent
Ensure that the ovalization is minimized to the extent
required to fit through the damper.
Figure 7.3 - 2-10-3 Rule
Figure 7.2
Figure 7.4
WARNING
ONLY use connector:
• Within the room, between appliance and ceiling or wall.
Connector shall NOT pass through:
• Attic or roof space
• Closet or similar concealed space
• Floor or ceiling
Maintain minimum clearances to combustibles
Fire Risk.
Follow Chimney Connector Manufacturer’s
Follow Chimney Connector Manufacturer’s
Instructions for Proper Installation.
WARNING
• ALWAYS maintain specified clearances around venting and
spacers.
• Install spacers as specified.
Failure to keep insulation or other material away from vent
pipe may cause fire.
Fire Risk.
Do NOT pack insulation or other combustibles
Do NOT pack insulation or other combustibles
between spacers.