Mitsubishi Electronics MS-AWA ユーザーズマニュアル

ページ / 28
12
2-7. INVERTER SYSTEM CONTROL
2-7-1. MUZ-A09/12/15/17
MUY-A15/A17
2-7-1-1. Inverter main power supply circuit
POWER P.C. BOARD
Power
supply
INVERTER P.C. BOARD
R64A R64B
CT
TR821
DB65
X64
L62
L63
C63A
C63B
C63C
DB61
L61
P
W
V
U
N
CT761
CT781
IPM
U
W
MC
V
+
Booster chopper circucuit
   SYMBOL
IPM
C63A/C63B/C63C
CT761/CT781
CT
DB61
R64A, R64B
X64
DB65
TR821
L61
                        NAME
INTELLIGENT POWER MODULE
SMOOTHING CAPACITOR
CURRENT TRANSFORMER
CURRENT TRANSFORMER
DIODE MODULE
CURRENT-LIMITING RESISTOR
RELAY
DIODE MODULE
SWITCHING POWER TRANSISTOR
REACTOR
                                               FUNCTION
It supplies three-phase AC power to compressor.
It stabilizes the DC voltage.
It measures the current of the compressor motor.
It measures the value of current which is supplied to the main power 
supply circuit.
It converts the AC voltage to DC voltage.
It absorbs the rush current not to run into the main power supply circuit 
when the electricity turns ON.
It short-circuits the resistance which restricts rush current during the 
normal operation after the compressor startup.
 
 Booster
  chopper
  circuit
Function of main parts
It improves power factor.
It rectifies AC and controls its voltage.
2-7-1-2. Outline of main power supply circuit
1. At the start of operation
    Main power supply circuit is formed when X64 (Relay) is turned ON at compressor startup.
    To prevent rush current from running into the circuit when power supply is turned ON, 
    R64A and R64B (Current-limitting resistor) are placed in sub circuit.
2. At normal operation
    
1
 When AC runs into POWER P.C. board, its external noise is eliminated in the noise filter circuit.
    
2
 After noise is eliminated from AC, it is rectified to DC by DB61 (Diode module). 
    
3
 DC voltage, to which AC has been rectified by process 
2
, is stabilized by C63A, C63B and C63C (Smoothing capacitor)
        and supplied to IPM (Intelligent power module).
    
4
 DC voltage, which has been stabilized in process 
3
, is converted to three-phase AC by IPM and supplied to
        compressor. 
    
5
 CT761 and CT781 (Current Transformer), which are placed in the power supply circuit to compressor, are used to 
         measure the value of phase current and locate the polar direction of rotor with algorithm. PWM (Pulse width modulation) 
         controls impressed voltage and frequency with those information.
OBT16--1.qxp  06.3.29 11:20 AM  Page 12