5-3.  Cooling Capacity
Indoor unit
KGS1411
Outdoor unit
CG1411
115V   single-phase   60Hz
TC
: Total cooling capacity (BTU/h)
SHC : Sensible heat capacity (BTU/h)
CI
: Compressor input (kW)
Rating conditions (# mark) are: Outdoor ambient temperature
95°F (35°C) D.B.
Indoor unit entering air temperature
80°F (26.7°C) D.B./67°F (19.4°C) W.B.
Rating Capacity: 9,000 BTU/h
Air Flow Rate: 282 CFM
Evaporator
Condenser
Ent. Temp.   °F (°C)
Ambient Temp.   °F (°C)
WB
DB
75
85
95
105
115
(23.9)
(29.4)
(35.0)
(40.6)
(46.1)
TC
9,120
8,680
8,170
7,610
6,980
CI
0.65
0.71
0.77
0.83
0.92
59
72 (22.2)
SHC
6,750
6,530
6,280
6,010
5,710
(15.0)
76 (24.4)
SHC
7,640
7,420
7,170
6,900
6,600
80 (26.7)
SHC
8,570
8,350
8,100
7,610
6,980
84 (28.9)
SHC
9,120
8,680
8,170
7,610
6,980
88 (31.1)
SHC
9,120
8,680
8,170
7,610
6,980
TC
9,460
9,040
8,590
8,070
7,520
CI
0.65
0.72
0.78
0.85
0.94
63
72 (22.2)
SHC
5,670
5,480
5,270
5,040
4,800
(17.2)
76 (24.4)
SHC
6,560
6,360
6,160
5,930
5,690
80 (26.7)
SHC
7,490
7,290
7,090
6,860
6,620
84 (28.9)
SHC
8,370
8,180
7,980
7,750
7,510
88 (31.1)
SHC
9,260
9,040
8,590
8,070
7,520
TC
9,820
9,430
# 9,000
8,520
8,000
CI
0.66
0.72
0.79
0.86
0.96
67
72 (22.2)
SHC
4,580
4,420
4,240
4,050
3,840
(19.4)
76 (24.4)
SHC
5,470
5,310
5,130
4,930
4,720
80 (26.7)
SHC
6,400
6,240
6,060
5,860
5,650
84 (28.9)
SHC
7,290
7,120
6,950
6,750
6,540
88 (31.1)
SHC
8,180
8,010
7,830
7,640
7,430
TC
10,340
9,980
9,590
9,170
8,700
CI
0.67
0.73
0.8
0.88
0.98
71
72 (22.2)
SHC
3,500
3,360
3,220
3,060
2,890
(21.7)
76 (24.4)
SHC
4,390
4,250
4,100
3,950
3,770
80 (26.7)
SHC
5,320
5,180
5,030
4,880
4,700
84 (28.9)
SHC
6,210
6,070
5,920
5,760
5,590
88 (31.1)
SHC
7,090
6,960
6,810
6,650
6,480
TC
10,550
10,210
9,850
9,430
8,990
CI
0.68
0.74
0.81
0.9
1
75
76 (24.4)
SHC
3,230
3,110
2,990
2,850
2,700
(23.9)
80 (26.7)
SHC
4,160
4,040
3,920
3,780
3,630
84 (28.9)
SHC
5,050
4,930
4,810
4,660
4,520
88 (31.1)
SHC
5,930
5,820
5,690
5,550
5,410