Sanyo KGS1411 ユーザーズマニュアル

ページ / 100
5
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
2-2-2.  Outdoor Unit (1)
Outdoor unit   CG1411
Control PCB
Part No.
CG1411
Controls
Microprocessor
Control circuit fuse
115V 5A
Gas Connection
Employed gas
Natural Gas (LP)
Gas connection
1/2 Female
Compressor
Type
Rotary (Hermetic)
Compressor model
C-1R71H2W
Nominal output
W
700
Compressor oil … Amount
cc
SUNISO 4GSD-T … 370
Coil resistance (ambient temp. 68°F (20°C))
Ω
C – R: 0.879
C – S: 3.609
Safety devices
Type
External (OLR)
Overload relay
MRA98962-9200
Operating temp.
Open °F (°C)
275 ± 9 (135 ± 5)
Close °F (°C)
156 ± 20 (69 ± 11)
Operating amp (ambient temp. 77°F (25°C))
Trip in 6 to 16 sec. at 34A
Run capacitor
µF
35
VAC
330
PTC starter
Part number
912X24E400XR20-PS2A
Resistance
Ω
47
Max voltage
300
Crank case heater
Fan & Fan Motor
Type
Propeller
Q’ty … Dia. and length
inch. (mm)
1 … 13-25/32 (ø 350)
Fan motor model … Q’ty
SB6-11H1P … 1
No. of poles … rpm (115V, High)
6 … 600
Nominal output
W
10
Coil resistance (ambient temp. 77°F (25°C))
Ω
BLU – BRN: 114.0 ± 7%
BLU – WHT: 153.4 ± 7%
Safety devices
Type
Thermostat
Operating temp.
Open °F (°C)
266 ± 14 (130 ± 8)
Close °F (°C)
174 ± 27 (79 ± 15) Automatic reclosing
Run capacitor
µF
5.0
VAC
220
Heat Exchanger Coil
Coil
Aluminum plate fin / Copper tube
Rows
1
Fin pitch
inch (mm)
1/16 (1.3)
Face area
ft
2
(m
2
)
2.73 (0.254)
External Finish
Acrylic baked-on enamel finish