Fujitsu fujitsu air conditioner concealed ceiling type ユーザーズマニュアル

ページ / 14
En-7
TEMPERATURE SET BACK TIMER
Instructions related to heating are applicable to “HEAT & COOL MODEL” (Reverse Cycle).
To set the temperature SET BACK timer
1
SET BACK
SU MO TU WE TH FR SA
3 6 9 12 15 18 21
If there is no existing
SET BACK tempera-
ture setting, “- -” will
be displayed for the
temperature.
2
SET
Press the SET BACK button to change to the SET BACK confi rmation display.
The SET BACK operating time and the set temperature will be displayed.
Press the SET button for 2
seconds or more.
3
l
  
Day setting
l
  
Operating time setting
DAY OFF
DAY
1
3
SET
2
SET
4
SU MO TU WE TH FR SA
3 6 9 12 15 18 21
ex.  When setting all days together
Follow steps 
3
 and 
4
 in “To set the WEEKLY timer” (p. 6). The DELETE button is also used as described in the procedures 
for the weekly timer.
l
  
Temperature setting
4
76
°F
76
°F
84
°F
SET BACK 
temperature
Normal 
temperature
SU MO TU WE TH FR SA
3 6 9 12 15 18 21
Press the SET TEMPERATURE buttons to
set the temperature (from 48 °F to 88 °F).
ex.  Operating time 3:00–10:00 P.M. 
(15:00–22:00)
ON
OFF
5
SET
Repeat steps 
3
 and 
4
.
Press the SET button for 2 
seconds or more to com-
plete the temperature SET 
BACK timer settings.
To start/cancel the temperature SET BACK timer operation
l
  
To start
SET BACK
SU MO TU WE TH FR SA
ex. Display during SET BACK timer operation
(The operating time will not be displayed.)
l
  
To cancel
SET BACK
1
DELETE
2
Press the SET BACK button, and then press the DELETE 
button while the SET BACK confi rmation display is dis-
played. Even if the SET BACK button is pressed again, the 
SET BACK timer will be cancelled.
Press the SET BACK button. The SET BACK confi rmation
display appears for 5 seconds, and then the timer starts 
automatically.
NOTES
(1)  The SET BACK timer only changes the set temperature, it cannot be used to start or stop air conditioner 
operation.
(2) The SET BACK timer can be set to operate up to two times per day but only one temperature setting can be 
used.
(3)  The SET BACK timer can be used together with the ON, OFF, and weekly timer functions.
(4)  The SET BACK operating time is displayed only in the SET BACK confi rmation display. (Refer to step 1 for the SET 
BACK confi rmation display.)
OM_9373117063-en.indd   Sec1:7