Avoid Service 
Checklist
Before  calling  for service, review  this  list. It may save you time and expense. This 
list  includes  common occurrences that are not the result of defective workmanship 
or materials in this appliance
OCCURRENCE                      SOLUTION
Air   conditioner    will   not          Wall plug disconnected. Push plug firmly into wall outlet.
Operate. 
House  fuse  blown  or  circuit  breaker tripped. Replace fuse with time delay type or 
reset circuit breaker.
Control is OFF. Turn control On and set to desired FAN or COOL setting.
Unit  turned off and on too quickly. Turn unit off and  wait 3 minutes before restarting.
Air  from  unit does not feel 
cold enough.
Room   temperature   below   60 F  (15 C).   Cooling   may   not   occur   until    room 
temperature rises above 60 F (15 C).
Temperature sensor touching cold coil, located behind air filter. Straighten away
from coil. 
Air    conditioner   cooling, 
but room is too warm- ice 
forming on cooling coil 
behind decorative front.
Outdoor    temperature  below  60 F(15 C). To  defrost  the  coil,  set   mode  to  FAN
position.
Air  filter  may  be  dirty. Clean filter. Refer to Care and Cleaning section. To defrost, 
set mode to FAN ONLY.
Temperature  is  too  low for night-time cooling. To defrost the coil, set to FAN ONLY 
mode. Then, set temperature to a higher number.
Air conditioner cooling, but 
room is too warm-NO ice
forming on cooling coil
behind decorative front.
Dirty air filter-air restricted. Clean air filter. Refer to Care and Cleaning section.
Temperature is  too high. Set temperature to a lower number.
Current device tripped. Preset RESET  button.
Reset to a lower temperature.
Compressor shut-off by changing modes. Wait approximately 3 minutes, and  listen 
for compressor to restart when set in the COOL mode.
Exhaust  set  at  OPEN  position.  Set  exhaust  at  CLOSED  position  for  maximum 
cooling.
Air   direction   louvers   positioned   improperly.   Position   louvers   for   better   air 
distribution.
Front of unit is blocked by drapes, blinds, furniture, etc.- restricts air distribution.
Clear blockage in front of unit. 
Doors,  windows,  registers,  etc,  open- cold  air  escapes.  Close  doors, windows,
registers, etc.
Unit  recently  turned  on  in hot room, allow additional time to remove “ stored heat”
from walls, ceiling, floor and furniture.
Air   conditioner  turns   on 
and off rapidly.
Dirty air filter- air restricted. Clean air filter. 
Outside temperature  extremely  hot. Set  FAN speed  to a faster setting to bring air
past cooling coils more frequently.
Noise when  unit is cooling
Air movement sound. This is normal. If too loud, set to a slower FAN setting.
Sound  of  fan hitting water-moisture removal system. This is normal when humidity 
is high. Close doors windows and registers.
Window   vibration-poor   installation.  Refer   to  installation  instructions  or  check 
with installer.
Water      dripping    INSIDE 
when unit is cooling.
Improper  installation.   Tilt  air  conditioner  slightly  to  the  outside  to  allow  water 
drainage. Refer to installation instructions - check with installer.
Water   dripping   OUTSIDE 
when unit is cooling.
Unit  removing  large  quantity  of  moisture  from humid room. This is normal during
excessively humid days. 
 11
Room too cold.
Setting too low. Increase temperature setting.