Friedrich 2003 ユーザーズマニュアル

ページ / 64
13
                                                                                                              Circuit Rating              Plug Face              Appearance
     Model                                                                                          Breaker or T-D Fuse        (NEMA#)            (Facing Blades)
    ALL SV and XQ MODELS, 
    KS10J10, KS12J10B, KS15J10, RS10J10, RS12J10A,
    RS15J10, SS08J10R, SS09J10C, SS10J10AR,                                       
    SS12J10AR, SS14J10R, SC06H10D,                                             
125V - 15A                5 - 15P
    EQ08J11, YQ06J10B, YS09J10B
    KS12J30B, KM18J30C, RS16J30A, 
    RM18J30A, SS12J30D, SS16J30A, SM18J30BR                             250V - 15A
               6 - 15P
    KM20J30, KM24J30, SM20J30, 
    SL25J30, SL28J30B*, ES12J33B,                                                 250V - 20A
              
6 - 20P
    ES16J33A, YS12J33                                                                            
    SL35J30, EM18J34B, EL25J35, EL35J35,
    YM18J34B, YL24J35C                                                                 
250V - 30A                6 - 30P
 
Optional 30 Amp Kit (618-869-00) is recommended in 208 Volt power supply areas that fall below 208 Volts.
  For more information, call the Friedrich Service Department. 
Due to a program of continuing improvement, specifications are subject to change without notice.
Installation Notes:
Supply Cord - All with right angle plug 6' on 115V; 5' on 230/208V.
Room air conditioners include accessories for window or thru-the-wall installation.
TWINTEMP
®
 models include accessories for thru-the-wall installation only.
Window mounting requires use of optional accessory kit as listed below:
MODEL                                             KIT NO.
EQ08J11, YQ06J10B                           WIKQ
ES12J33B, ES16J33A,                        WIKS
YS09J10B, YS12J33
EM18J34B, YM18J34B                       WIKM
EL25J35, EL35J35,                             WIKL
YL24J35C
Wire Size
Use  ONLY wiring size recommended for
single outlet branch circuit.
Fuse/Circuit
Use ONLY type and size fuse or HACR
Breaker
circuit breaker indicated on unit's rating
plate.  Proper
current protection to the unit
is the responsibility of the owner.
Grounding
Unit MUST be grounded from branch circuit
through service cord to unit, or through
separate ground wire provided on permanently
connected units. Be sure that branch circuit
or general purpose outlet is grounded.
Receptacle
The field supplied outlet must match plug on
service cord and be within reach of service
cord.
Do NOT alter the service cord or plug.  Do
NOT use an extension cord.  Refer to the table
above for proper receptacle and fuse type.
Electrical Rating T
Electrical Rating T
Electrical Rating T
Electrical Rating T
Electrical Rating Tables
ables
ables
ables
ables
Electric shock hazard.
Turn off electric power before service or installation.
All electrical connections and wiring MUST be installed by a qualified
electrician and conform to the National Electrical Code and all local
codes which have jurisdiction.
Failure to do so can result in property damage, personal injury and/
or death.
The consumer - through the AHAM Room Air Conditioner
Certification Program - can be certain that the AHAM
Certification Seal accurately states the unit's cooling and
heating capacity rating, the amperes and the energy efficiency
ratio.