GENERAL TROUBL-SHOOTING
TROUBLE
POSSIBLE CAUSE
REMEDY
Pilot will not ignite or does not hold.
Gas not reaching unit.
Main “gas cock knob” not  in 
ON position.
Air pocket or clog in gas line.
Defective wiring or poor con-
nection at pilotstat power unit.
Defective switching across 
either the water level control or 
pressure switches.
Defective gas valve.
1.
2.
3.
4.
5.
6.
Check to make sure gas is  on 
and gas line is purged of air.
Depress and turn “main gas 
cock” to pilot position - (refer to 
lighting instructions).
Purge or blow out gas line.
Check - replace or tighten.
Make continuity check - replace 
units that are defective.
Replace gas valve.
1.
2.
3.
4.
5.
6.
Water enters boiler very slowly.
Clogged strainer screen on 
water fill solenoid valve
Debris or lime accumulation on 
seat of  water fill valve.
1.
2.
Clean or replace strainer 
screen. (P/N 08-4871).
Clean valve seat
1.
2.
Boiler overfills with water
Probes scaled.
Water supply valve fails to 
close.
Defective water level control.
1.
2.
3.
Clean.
Clean valve seat or replace 
valve.
Follow the test procedure on 
page 11. Replace if defective.
1.
2.
3.
Main Burners will not ignite or will 
not remain lighted.
No water in boiler.
Main gas cock or supply line 
not open.
Pressure switch set too low.
No voltage to gas valve.
Gas valve defective.
1.
2.
3.
4.
5.
Check to be sure water switch 
is on. Check to be sure main 
water supply is on and the elec-
trical supply to unit is on.
Open.
Reset - if continuity check 
shows to be defective - replace.
Check main fuse.
Replace.
1.
2.
3.
4.
5.
Boiler fails to build up any pressure 
when the water is at the correct 
level and the fuel switch is turned 
on.
Check to see that main gas is 
turned on.
Check to see that gas valve is 
in burners “on” position.
Current flow is broken at water 
level control (ascertain with 
continuity check).
Current flow is broken at pres-
sure control or high limit control 
switches (ascertain with conti-
nuity check).
1.
2.
3.
4.
Turn on.
Turn to burners “on”.
Check for voltage thru right 
side of control board, replace if 
defective.
Re-adjust to proper setting - 
refer to instruction for re-adjust-
ment, replace if defective.
1.
2.
3.
4.
Water level in gauge glass 
fluctuates up and down.
Top shutoff valve on water 
gauge glass is closed.
1.
Open.
1.