Runco Home Theater Projection System ユーザーズマニュアル

ページ / 152
LightStyle™ LS-12HBd Installation/Operation Manual
117 
PRE
L
IMINAR
Y
6.2 
Using Discrete IR 
Codes
The Dimension Digital Controller accepts commands in the form of IR signals that conform 
to the NEC protocol. Each Dimension Digital Controller remote control button has an NEC 
control code associated with it. 
You can use these codes to program a third-party, “universal” remote control unit to work 
with the Dimension Digital Controller. These third-party products usually come with a 
computer software application for this purpose. For more information, consult the 
documentation provided with the remote control unit. 
IR Command Protocol
The IR control codes have the following characteristics:
• Each code consists of the following:
• A leader pulse (a modulated pulse of 9 ms followed by a non-modulated pulse of 
4.5 ms);
• 16 address bits. The default address is 82 09 (0x2011, binary 
00100000 00010001). To change it, select Remote Control from the Service menu 
and follow the steps given on page 83
• 16 data bits: eight (8) bits for the command followed by the logical inverse of the 
command; and
• An end pulse (a modulated pulse of 0.56 ms, similar to the modulated pulse in the 
‘0’ and ‘1’ bits).The end of the modulated pulse constitutes the end of the data 
transmission. 
• The carrier frequency is 38 kHz, with the modulated pulses having a 33% duty cycle. 
• Commands are sent at a maximum rate of 9 Hz.
For example, here is the NEC control code for the ON button on the Dimension Digital 
Controller remote control unit (assuming the default address is used):  
Figure 6-1 shows the pulse train for this command. 
Figure 6-1. NEC Protocol Message Format
Hex
20
11
01
FE
Binary
00100000
00010001
00000001
11111110
Function
Address Byte 1
Address Byte 2
Command
Command
(Logical Inverse)
9 ms
13.5 ms
27 ms
27 ms
Address Byte 1
Leader Pulse
Address Byte 2
Command Byte
Command Byte (logical inverse)
0 0 1   0 0 0 0 0 0 0 0 1   0 0 0 1
0 0 0 0 0 0 0 1
1   1   1   1   1   1   1   0
4.5 ms
End Pulse