Runco RS-900 Series RS1100 Series ユーザーガイド

ページ / 104
RS-900 and RS1100 Series Installation/Operation Manual
41 
PRE
L
IMINAR
Y
5.
Use the Height/Y Adjustment T-Screws/Washers (item #3), Pitch Adjustment 
T-Screws/Washers (item #4) and T-Nuts (item #9) to attach the Pitch Adjustment 
Yoke and Lens Adapter Ring to the Anamorphic Lens Holder. The Yoke should be 
as close to the primary lens as possible.
6.
Attach the lens to the Lens Adapter Ring by threading it clockwise. 
Figure 3-21. Attaching the Anamorphic Lens to the Lens Ring
Configure Lens Motor Trigger: CineWide with AutoScope maintains constant image 
height independent of the aspect ratio, while using the full display resolution of the 
projector. It accomplishes this by moving the anamorphic lens in front of the primary lens 
when widescreen material is being viewed. When the viewer transitions back to 16:9 or 
4:3 source material, the anamorphic lens moves out of the light path.
To configure the lens motor trigger on the RS-900/RS1100 for proper AutoScope 
operation: 
1.
Press MENU on the remote control.
2.
Select Setup from the Main menu and press ENTER
3.
Use the number buttons on the remote to enter the Setup menu passcode when 
prompted and press ENTER again. Then, press MENU on the remote control. 
4.
Select 12-volt Trigger from the Setup menu. 
5.
Set the 12-volt Trigger to “Cinema.” This enables the lens motor to move the 
anamorphic lens into position (in front of the primary lens) when the Cinema or Virtual 
Cinema aspect ratio is selected. 
Lens threads into ring
FO
CU
S