Honeywell CT8602 ユーザーズマニュアル

ページ / 24
13
69-1532
Time Format (Feature Number 16)
Time format options are:
0 = 12-hour clock (preset).
1 = 24-hour clock.
To change time format:
Press  
once.
Press 
 to return to main display.
Heating Temperature Range Stops (Feature Number 34)
Temperature range options are:
90 = highest setting for heating setpoint (preset)
40 to 89 = temperature range (1°F increments) heating setpoint can be set to.
Cooling Temperature Range Stops (Feature Number 35)
Temperature range options are:
45 = lowest setting for cooling setpoint (preset)
46 to 99 = temperature range (1°F increments) cooling setpoint can be set to.
Factory Set Function (Feature Number 37)
Do not change this setting.
STEP 9. SET THE CLOCK
Set Current Day and Time
NOTE:
On initial power-up, the screen flashes 1:00 pm until you press a key.
Press .
Press 
 until screen shows current day.
Press Time 
 or 
 until screen shows current time. (Tapping the 
 will advance the time in one 
hour increments).
M18753
Run
Program
M18748
M18749
M18754
Set Current
Day/Time
Day
Set Current
Day/Time