cx400/px400 Sub. pump • operation and partS manual — rev. #1 (12/03/10) — page 17
Hose connections
1.  Connect a 2-inch hose to the discharge port on the 
pump as shown in Figure 11. Make sure that hose is 
attached correctly to the discharge port. 
attaching lifting rope
1.  Attach a suitable lifting cable (rope) to the carrying 
handle (Figure 11) on the pump and lower the pump 
into place. For applications where there is an excessive 
amount of mud, grit or silt, the use of a support platform 
is desirable. When pumping water from swimming pool 
type applications where there is little or no debris, the 
support platform is not required.
Figure 11. Submersible Pump 
Upright Position (Correct)
2.  Make sure the pump is always placed in an upright 
position (Figure 11, and not tilted (Figure 12). Never 
position  the  pump  directly  on  a  soft,  loose  bottom. 
Remember to attain maximum pumping capacity and 
prevent excessive wear.  Position the pump so it will 
not burrow itself into sand or clay.
LIFTING
ROPE
2-INCH
DISCHARGE
HOSE
SUPPORT
PLATFORM
CARRYING
HANDLE
POWER
CORD
115 VAC
POWER
PLUG
GREEN
BLACK
EXTERNAL
1Ø 115 VAC, 60 Hz
POWER SOURCE
CIRCUIT
BREAKER
L
N
WHITE
GND. BUS
SUBMERSIBLE
PUMP
OperatiOn
Figure 12. Submersible Pump 
Tilted Position (Incorrect)
pump power connections (no control box)
1.  Make sure circuit breaker supplying power to pump 
motor is in the 
oFF position.
2.  Insert  the  power  cable  plug  (Figure  11)  into  the 
appropriate  power  source  receptable. The  correct 
source  voltage  for  this  pump  is  115 VAC,  60  Hz, 
single-phase.
3.  If all of the pump's electrical requirements have been 
met, place the circuit breaker or power ON/OFF switch 
in the 
on position.
4.  Wait a few seconds and water should begin to flow 
from the discharge hose.
5.  If water is not flowing from the discharge hose or not 
flowing  freely  after  a  few  minutes,  place  the  circuit 
breaker or ON/OFF switch in the 
oFF position and 
check the system for leaks.
SUBMERSIBLE
PUMP
NOTICE
When connecting the pump directly to a power source 
(no  control  box),  it  is  recommeded  that  personnel 
monitor  the  pump  while  in  operation.  Severe  pump 
damge can occur if left unattended.
For unattended operation Multiquip recommends the 
use of the CB3 control box.