3100 Wood Stove Series (ACC)
R
B. Clearances to Combustibles (UL and ULC)
BACKWALL / SIDEWALL 
A
B
C
D
E
F
E
F
CORNER INSTALLATION
G
H
*
90° OFF TOP 
UP & OUT CEILING 
CLEARANCE
STOVE TO CEILING 
CLEARANCE 
C
D
ALCOVE TOP VIEW 
G
A
B
ALCOVE SIDE VIEW
NOTE:  Clearances may only be reduced by means 
approved by the regulatory authority having jurisdiction
Fire Risk.
•  Comply with all minimum clearances to 
combustibles as specified.
•  Failure to comply may cause house fire.
WARNING
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches & (Millimeters)
 
NOTE:  All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar. 
 
INSTALLATION: Full Vertical OR Horizontal with Minimum 2 FT Vertical Off Stove Top
SINGLE WALL PIPE 
    Flat Top Model 
15.25 (387)  11.75 (298)  25.5 (648)  16 (406) 
8 (203) 
17 (432) 
48 (1220)  12 (305)
    Step-Top Model 
12 (305)   8.5 (216) 
22 (559)  12.5 (318) 
5.5 (140  14.5 (368)  48 (1220)  12 (305) 
   
   
DOUBLE WALL PIPE 
    Flat Top Model 
10.5 (267)  6.5 (165) 
22 (559) 
13 (330) 
6.5 (165)  15.5 (394)  48 (1220) 
9 (229)
    Step-Top Model 
10 (228) 
6 (152) 
20.5 (521)  11 (279) 
4 (102) 
13 (330) 
48 (1220) 
9 (229) 
   
INSTALLATION: 90° Elbow Off Top of Stove Through Backwall
SINGLE WALL PIPE 
   Flat Top Model 
12 (305) 
8.5 (216) 
22 (559) 
13 (330) 
8 (203) 
17 (432) 
48 (1220)  12 (305)
   Step-Top Model 
10 (254) 
6 (152) 
20.5 (521)  11 (279) 
5.5 (140)  14.5 (368)  48 (1220)  12 (305) 
   
 
DOUBLE WALL PIPE 
   Flat Top Model 
8 (203) 
4.5 (114)  17.5 (445)  8.5 (216) 
6.5 (165)  15.5 (394)  48 (1220) 
9 (229)
   Step-Top Model 
10 (254) 
6 (152) 
20.5 (521)  11 (279) 
4 (102) 
13 (330) 
48 (1220) 
9 (229) 
INSTALLATION: ALCOVE  Six inch (6") (152mm) diameter listed Double Wall air insulated connector pipe with UL103 HT* listed 
factory-built Class "A" chimney, or a masonry chimney.  (Mobile Home must be equipped with a spark arrestor). Maximum depth of Alcove 
shall be no more than 48 inches (1220mm) with a minimum height of 48 inches (1220mm) to top of unit, and the referenced clearances.
     *In Canada must comply with CAN/ULC-S269 M87 for the 650
o
C Factory-built chimney.
DOUBLE WALL PIPE 
    Flat Top Model 
11.75 (298)  8.25 (210)  23.5 (597)  14.5 (368) 
N/A 
N/A 
48 (1220) 
*
    Step-Top  Model 
10 (254) 
6.5 (152)  20.5 (521)  11 (279) 
N/A 
N/A 
48 (1220) 
*
 
* SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED
 
 
 
 
 
 
  
NOTE:  Service Space
In order to replace the tube channel assembly a clearance 
of 19 inches (48mm) is required on the right side of stove 
in order to remove the tubes with the stove in place.  
If space is not available, the stove will have to be discon-
nected from the chimney to proceed with the tube replace-
ment.