Mitsubishi Electronics A950GOT ユーザーズマニュアル

ページ / 124
8.2 System Configuration when EMC Directive is Applicable
8.2.5 About the cable used
8 - 8
1
OV
E
R
VI
EW
2
SYSTE
M
CO
N
F
IG
UR
A
T
IO
N
3
PERFORMA
N
CE
4
NAMES
 OF
 
THE P
A
R
T
S A
ND 
THEIR SE
TTI
N
GS
5
ROUGH 
PRE-
OPE
R
A
T
IO
PROC
E
DUR
E
6
HANDLING
7
MAINTENANCE AND 
INS
P
E
CT
IO
N
8
E
M
C DIRECTIV
E
(2) For A956WGOT
Be sure to use the communication boards/communication modules shown below with A956WGOT. 
If communication modules/communication boards other than those shown below are used, they are 
not applicable to the EMC directive.
Confirm the hardware version with the products rating plate.
(Products that the EMC directive applies to are marked with the CE mark logo.)
8.2.5
About the cable used
If making the GOT applicable to the EMC directive, be sure to use the cables shown below.
: EMC directive applicable 
: EMC directive not applicable
To make applicable to the EMC directive, each cable (including user created cables) 
must be manufactured.
Refer to section 8.3.2 for the cable manufacturing method.
Connection Format
Communication board/module
Bus connection
A9GT-50WBUSS (Hardware version B or later)
A9GT-BUSSU (Hardware version B or later)
A9GT-BUS2SU (Hardware version B or later)
CPU Direct connection
RS-232C
A9GT-50WRS2 (Hardware version B or later)
RS-422
A9GT-50WRS4 (Hardware version B or later)
Computer link connection
RS-232C
A9GT-50WRS2 (Hardware version B or later)
RS-422
A9GT-50WRS4 (Hardware version B or later)
CC-Link connection
A8GT-J61BT13 (Hardware version E or later)
Ethernet connection
A9GT-J71E71-T (Hardware version C or later)
Connection format
Cable
EMC Directive
Bus connection
A/QnACPU
AC06/12/30/50B, AC12/30/50B-R,
A1SC07/12/30/50B, A1SC05/07/30/50NB,
A8GT-C12/30/50NB, A370C12/25B,
A9GT-J2C10B, A8GT-C100/200/300EXSS,
A8GT-C100/200/300BS,    A8GT-C100/200/300EXSS-1
QCPU (Q mode)
QC06/12/30/50/100B, A9GT-QC150/200/250/300/350BS
CPU direct con-
nection
RS-232C communication
QC30R2
RS-422 communication
AC30/100/300R4-25P
Computer link 
connection
RS-232C communication
User created cable
RS-422 communication
AC30/100/300R4-25P, User created cable
CC-Link connection
CC-Link dedicated cable
Ethernet connection
Category 5 Twisted pair shielded cable
DATE
MADE  IN  JAPAN
US LISTED 80M1   IND.CONT.EQ.
GRAPHIC OPERATION TERMINAL
MODEL
POWER
 
      IN   24VDC 
MITSUBISHI ELECTRIC CORPORATION
BD992C189H02
C
A951GOT-SBD-M3
MAX 12W 
0105 LP 
Compliant standard marking is provided.
Hardware version
 L P 
PASSED