Mitsubishi Electronics MR-J2S- CP ユーザーズマニュアル

ページ / 357
 
 
4 -  14 
4. OPERATION 
 
4.2.5 Automatic operation timing chart 
 
The timing chart is shown below. 
ON
OF 
ON
OF 
ON
OF 
ON
OF 
ON
OF 
ON
OF 
0r/min
ON
OF 
ON
OF 
2
1
ON
OF 
1
2
Automatic/manual
selection (MD0)
Servo-on (SON)
Forward rotation
start (ST1)
Reverse rotation
start (ST2) (Note 1)
Point table No.
Servo motor speed
Forward
rotation
Reverse
rotation
In position (INP)
Rough match (CPO)
Movement finish
(MEND)
Point No. output
(PT0 to PT4)
Ready (RD)
Trouble (ALM)
Point table No. 1
(Note 2)
3ms or more
5ms or more
3ms or less
Point table No. 2
3ms or more
Note 1: Reverse rotation start (ST2) is invalid in the absolute value command system and absolute value command/incremental
             value command specifying system.
         2: External input signal detection delays by the input filter setting time of parameter No. 2. Also, make up a sequence
             that will change the point table selection earlier by the time that takes into account the output signal sequence from
             the controller and the variation of a signal change due to the hardware.
5ms or more