Mitsubishi Electronics MR-J2S- CP ユーザーズマニュアル

ページ / 357
 
 
4 -  24 
4. OPERATION 
 
4.3.2 Manual pulse generator operation 
(1) Setting 
Set the input signal and parameters as follows according to the purpose of use. In this case, the point 
table No. selection 1 to 5 (DI0 to DI4) are invalid. 
Item Setting 
method Description 
Manual operation mode selection 
Automatic/manual selection (MD0) 
Open MD0-SG (OFF). 
Manual pulse generator 
multiplication 
Parameter No.1 
Set the multiplication ratio of servo 
motor rotation to the pulses generated by 
the manual pulse generator. 
For more information, refer to (3) of this 
section. 
Servo motor rotation direction 
Parameter No.1 
Refer to (2) of this section. 
 
(2) Servo motor rotation direction 
Servo motor rotation direction 
Parameter No. 1 setting 
Manual pulse generator: forward rotation 
Manual pulse generator: reverse rotation 
CCW rotation 
CW rotation 
CW rotation 
CCW rotation 
Forward rotation
CCW
CW
 
(3) Manual pulse generator multiplication 
(a) Using the parameter for setting 
Use parameter No.1 to set the multiplication ratio of the servo motor rotation to the manual pulse 
generator rotation. 
Parameter No. 1 setting 
Multiplication ratio of servo motor rotation to manual 
pulse generator rotation 
Moving distance 
0
 1 
time 
1[ m] 
1
 10 
times 
10[ m] 
2
 100 
times 
100[ m]