5. PARAMETERS 
 
5. PARAMETERS 
 CAUTION 
Never adjust or change the parameter values extremely as it will make operation 
instable.
 
 
5.1 Parameter list 
5.1.1 Parameter write inhibit 
POINT 
 
Set "000E" when using the MR Configurator (servo configuration 
software) to make device setting. 
After setting the parameter No.19 value, switch power off, then on to 
make that setting valid. 
 
In the servo amplifier, its parameters are classified into the basic parameters (No.0 to 19), expansion 
parameters 1 (No.20 to 53), expansion parameters 2 (No.54 to 77) and special parameters (No.78 to 90) 
according to their safety aspects and frequencies of use. In the factory setting condition, the customer can 
change the basic parameter values but cannot change the expansion parameter 1,2 values and special 
parameter values. When fine adjustment, e.g. gain adjustment, is required, change the parameter No.19 
setting to make the expansion parameters write-enabled. 
The following table lists the parameters whose values are made valid for reference/write by setting 
parameter No. 19. Operation can be performed for the parameters marked  . 
 
Parameter No.19 
setting 
Operation 
Basic parameters 
No.0 to No.19 
Expansion parameters 1 
No.20 to No.53 
Expansion parameters 2 
No.54 to No.77 
special parameters (No.78 to 90)
Reference 
 
 
 
0000 
(initial value) 
Write 
 
 
 
Reference No.19 
only 
 
 
000A 
Write No.19 
only 
 
 
Reference 
 
 
 
000B 
Write 
 
 
 
Reference 
 
 
 
000C 
Write 
 
 
 
Reference 
 
 
 
000E 
Write