Mitsubishi Electronics MR-J2S- CP ユーザーズマニュアル

ページ / 357
 
 
9 -  4 
9. SPECIAL ADJUSTMENT FUNCTIONS 
  
(2) Parameters 
The operation of adaptive vibration suppression control selection (parameter No.63). 
Parameter No. 63
Adaptive vibration suppression control selection
Choosing "valid" or "held" in adaptive vibration suppression 
control selection makes the machine resonance suppression 
filter 1 (parameter No. 61) invalid.
0: Invalid
1: Valid
Machine resonance frequency is always detected to 
generate the filter in response to resonance, suppressing 
machine vibration.
2: Held
Adaptive vibration suppression control sensitivity selection
Set the sensitivity of detecting machine resonance.
0: Normal
1: Large sensitivity
Filter characteristics generated so far is held, and detection of
machine resonance is stopped.
 
 
POINT 
 
Adaptive vibration suppression control is factory-set to be invalid 
(parameter No. 63: 0000). 
The filter characteristics generated are saved in the EEP-ROM every 60 
minutes since power-on. At next power-on, vibration suppression control is 
performed with this data saved in the EEP-ROM being used as an initial 
value. 
Setting the adaptive vibration suppression control sensitivity can change 
the sensitivity of detecting machine resonance. Setting of "large sensitivity" 
detects smaller machine resonance and generates a filter to suppress 
machine vibration. However, since a phase delay will also increase, the 
response of the servo system may not increase. 
 
9.4 Low-pass filter 
(1) Function 
When a ballscrew or the like is used, resonance of high frequency may occur as the response of the 
servo system is increased. To prevent this, the low-pass filter is factory-set to be valid for a torque 
command. The filter frequency of this low-pass filter is automatically adjusted to the value in the 
following expression. 
Filter frequency(Hz)
 (1   Ratio of load inertia moment to servo motor inertia moment setting   0.1)
2
Speed control gain 2 setting   10
 
(2) Parameter 
Set the operation of the low-pass filter (parameter No. 63.) 
Parameter No. 63
Low-pass filter selection
0: Valid (automatic adjustment)     initial value
1: Invalid
 
POINT 
 
In a mechanical system where rigidity is extremely high and resonance is 
difficult to occur, setting the low-pass filter to be "invalid" may increase 
the servo system response to shorten the settling time.