11. TROUBLESHOOTING 
 
11.2.2 Remedies for alarms 
CAUTION 
When any alarm has occurred, eliminate its cause, ensure safety, then reset the 
alarm, and restart operation. Otherwise, injury may occur. 
If an absolute position erase alarm (AL.25) occurred, always make home position 
setting again. Otherwise, misoperation may occur. 
 
POINT 
 
When any of the following alarms has occurred, always remove its cause 
and allow about 30 minutes for cooling before resuming operation. If 
operation is resumed by switching control circuit power off, then on to reset 
the alarm, the servo amplifier and servo motor may become faulty. 
Regenerative error (AL.30) 
Overload 1 (AL.50) 
Overload 2 (AL.51) 
The alarm can be deactivated by switching power off, then on press the 
"SET" button on the current alarm screen or by turning on the reset (RES). 
For details, refer to section 11.2.1. 
 
When an alarm occurs, the trouble (ALM) switches off and the dynamic is operated to stop the servo 
motor. At this time, the display indicates the alarm No. 
The servo motor comes to a stop. Remove the cause of the alarm in accordance with this section. The 
optional MR Configurator (servo configuration software) may be used to refer to the cause. 
Display Name 
Definition 
Cause 
Action 
1. Power supply voltage is low. 
2. There was an instantaneous 
control power failure of 60ms or 
longer. 
3. Shortage of power supply capacity 
caused the power supply voltage to 
drop at start, etc. 
4. The bus voltage dropped to the 
folllowing value or less.  
MR-J2S- CP: 200VDC 
MR-J2S- CP1: 158VDC 
Review the power supply. 
AL.10 Undervoltage Power supply 
voltage dropped. 
MR-J2S- CP: 
160VAC or less 
MR-J2S- CP1: 
83VAC or less 
5. Faulty parts in the servo amplifier 
Checking method
Alarm (AL.10) occurs if power is 
switched on after disconnection 
of all cables but the control
circuit power supply cables.
 
Change the servo amplifier. 
AL.12  Memory error 1  RAM, memory fault 
AL.13 Clock 
error  Printed 
board 
fault 
Faulty parts in the servo amplifier 
Checking method
Alarm (any of AL.12 and 13) 
occurs if power is switched on
after disconnection of all cables 
but the control circuit power 
supply cables.
 
Change the servo amplifier. 
1. Faulty parts in the servo amplifier 
Checking method
Alarm (AL.15) 
occurs if power is switched on
after disconnection of all cables 
but the control circuit power 
supply cables.
 
AL.15  Memory error 2  EEP-ROM fault 
2. The number of write times to EEP-
ROM exceeded 100,000. 
Change the servo amplifier. 
1. Encode connector (CN2) 
disconnected. 
Connect correctly. 
2. Encoder fault 
Change the servo motor. 
AL.16 Encoder 
error 
Communication 
error occurred 
between encoder 
and servo amplifier.  3. Encoder cable faulty 
(wire breakage or short) 
Repair or change the cable.