Mitsubishi Electronics MR-J2S- CP ユーザーズマニュアル

ページ / 357
 
 
14 -  1 
14. OPTIONS AND AUXILIARY EQUIPMENT
14. OPTIONS AND AUXILIARY EQUIPMENT 
WARNING 
Before connecting any option or peripheral equipment, turn off the power and wait 
for 15 minutes or more until the charge lamp turns off. Then, confirm that the 
voltage between P and N is safe with a voltage tester and others. Otherwise, an 
electric shock may occur. In addition, always confirm from the front of the servo 
amplifier whether the charge lamp is off or not. 
 
CAUTION 
Use the specified auxiliary equipment and options. Unspecified ones may lead to a 
fault or fire. 
 
14.1 Options 
14.1.1 Regenerative options 
CAUTION 
The specified combinations of regenerative options and servo amplifiers may only 
be used. Otherwise, a fire may occur. 
 
(1) Combination and regenerative power 
The power values in the table are resistor-generated powers and not rated powers. 
Regenerative power[W] 
Servo amplifier 
Built-in regenerative 
resistor 
MR-RB032
[40 ] 
MR-RB12 
[40 ] 
MR-RB32 
[40 ] 
MR-RB30 
[13 ] 
(Note) 
MR-RB50 
[13 ] 
MR-RB31 
[6.7 ] 
(Note) 
MR-RB51 
[6.7 ] 
MR-J2S-10CP(1)  
30      
 
MR-J2S-20CP 
(1) 
10  30 
100 
     
MR-J2S-40CP 
(1) 
10  30 
100 
     
MR-J2S-60CP 10  30 
100 
     
MR-J2S-70CP 20  30 
100 
300 
    
MR-J2S-100CP 
20  30 
100 
300 
    
MR-J2S-200CP 
100     
300 
500 
  
MR-J2S-350CP 
100     
300 
500 
  
MR-J2S-500CP 
130     
300 
500 
  
MR-J2S-700CP 
170       
300 
500 
Note. Always install a cooling fan. 
 
(2) Selection of the regenerative option 
(a) Simple selection method 
In horizontal motion applications, select the regenerative option as described below. 
When the servo motor is run without load in the regenerative mode from the running speed to a 
stop, the permissible duty is as indicated in section 5.1 of the separately available Servo Motor 
Instruction Manual. 
For the servo motor with a load, the permissible duty changes according to the inertia moment of 
the load and can be calculated by the following formula. 
Permissible
duty
Permissible duty for servo motor with no load (value indication section 5.1 in Servo Motor Instruction Manual)
(m   1)
ratedspeed
running speed
[times/min]
2
where m
load inertia moment/servo motor inertia moment
 
From the permissible duty, find whether the regenerative option is required or not. 
Permissible duty   number of positioning times [times/min] 
Select the regenerative option out of the combinations in (1) of this section.