(b) FR-BR resistor unit 
[Unit: mm] 
2      C
Control circuit
terminal
Main circuit
terminal
W1    1
Approx. 35
Approx. 35
C
C
W    5
(Note)
(Note)
 
Note. Ventilation ports are provided on both sides and the top. The bottom is open.  
 
Resistor 
unit 
W W1 H H1 H2 H3 D D1 C 
Approximate 
mass 
[kg]([Ib]) 
FR-BR-15K 170  100  450  410  20 432  220 3.2  6 
15(33.1) 
FR-BR-30K 340  270  600  560  20 582  220 4  10  30(66.1) 
 
14.1.3 Power regeneration converter 
When using the power regeneration converter, set "01
 
" in parameter No.0. 
(1) Selection 
The converters can continuously return 75% of the nominal regenerative power. They are applied to 
the servo amplifiers of the MR-J2S-500CP and MR-J2S-700CP. 
Power 
regeneration 
converter 
Nominal 
regenerative 
power (kW) 
Servo amplifier 
FR-RC15 15 
FR-RC30 30 
MR-J2S-500CP 
MR-J2S-700CP 
 
 
 
0
50
75
100
150
500
300
200
100
50
30
20