15 -  1 
15. COMMUNICATION FUNCTIONS
 
15. COMMUNICATION FUNCTIONS 
This servo amplifier has the RS-422 and RS-232C serial communication functions. These functions can be 
used to perform servo operation, parameter changing, monitor function, etc. 
However, the RS-422 and RS-232C communication functions cannot be used together. Select between RS-
422 and RS-232C with parameter No.16. (Refer to section 15.2.2.) 
 
15.1 Configuration 
15.1.1 RS-422 configuration 
(1) Outline 
Up to 32 axes of servo amplifiers from stations 0 to 31 can be operated on the same bus. 
CHARGE
MITSUBISHI
CHARGE
MITSUBISHI
CHARGE
MITSUBISHI
 
RS-422
Controller such as
personal computer
RS-232C/
RS-422
converter
To CN3
Axis 1 (Station 0)
Axis 2 (Station 1)
Axis 32 (Station 31)
Unavailable as option.
To be prepared by customer.
To CN3
To CN3
Servo amplifier
Servo amplifier
Servo amplifier
 
(2) Cable connection diagram 
Wire as shown below. 
RS-422
output unit
RDP
RDN
SDP
SDN
GND
GND
(Note 3) 30m (98.4ft) or less
(Note 1)
Axis 1 servo amplifier
CN3 connector
5
15
9
19
11
1
10
Plate
RDP
RDN
SDP
SDN
LG
LG
TRE
SD
(Note 1)
Axis 2 servo amplifier
CN3 connector
5
15
9
19
11
1
10
RDP
RDN
SDP
SDN
LG
LG
TRE
SD
Plate
(Note 1)
Axis 32 (last axis)
servo amplifier
CN3 connector
5
15
9
19
11
1
10
RDP
RDN
SDP
SDN
LG
LG
TRE
SD
Plate
(Note 2)
 
Note 1. Connector set MR-J2CN1 (3M) 
Connector: 10120-3000PE 
Shell kit: 10320-52F0-008 
2. In the last axis, connect TRE and RDN. 
3. 30m (98.4ft) or less in environment of little noise.