Mitsubishi Electronics MR-J2S- CP ユーザーズマニュアル

ページ / 357
 
 
3 -  16 
3. SIGNALS AND WIRING 
 
3.4.3 Override 
POINT 
 
When using the override (VC), make the override selection (OVR) device 
available. 
 
The override (VC) may be used to change the servo motor speed. The following table lists the signals and 
parameter related to the override. 
Item Name 
Remarks 
Analog input signal 
Override (VC) 
 
Contact input signal 
Override selection (OVR) 
MR Configurator (servo configuration software) 
setting required. 
Parameter 
No.25 override offset 
999 to 999mV 
 
(1) Override (VC) 
By applying a voltage ( 10 to  10V) to the override (VC) terminal, change values can be set from 
outside consecutively. The following graph shows the relationship between the input voltage and the 
ratio of actual speed to preset speed. 
Override selection (OVR)
OVR
SG
VC
LG
Servo amplifier
Override (VC)
Override (VC) application voltage
Rat
io o
f ac
tual
 s
pee
d t
preset
 speed
10
10
200
[%]
0
[V]
0
100
SD
10 to   10V
 
(2) Override selection (OVR) 
Used to make the override (VC) valid or invalid. 
Servo amplifier
Override selection
(OVR)
O
verri
de
Override (VC)
   10 to  10V
Motor
 
Using the override selection (OVR), choose a change value as follows. 
 
(Note)  
External input signal 
OVR 
Speed change value 
0 No 
change 
Override (VC) setting is made valid. 
Note. 0 : Off (open) across OVR-SG 
1 : On (shorted) across OVR-SG 
 
(3) Override offset (parameter No.25) 
Using parameter No.25, the offset voltage can be set relative to the input voltage for the override (VC). 
The setting is between  999 to 999mV.