3. SIGNALS AND WIRING 
 
3.7 Input power supply circuit 
 CAUTION 
Always connect a magnetic contactor (MC) between the main circuit power supply 
and L
1
L
2
and L
3
 
of the servo amplifier, and configure the wiring to be able to shut 
down the power supply on the side of the servo amplifier’s power supply. If a 
magnetic contactor (MC) is not connected, continuous flow of a large current may 
cause a fire when the servo amplifier malfunctions. 
Use the trouble signal to switch power off. Otherwise, a regenerative transistor 
fault or the like may overheat the regenerative resistor, causing a fire. 
 
3.7.1 Connection example 
Wire the power supply and main circuit as shown below so that the servo-on (SON) turns off as soon as 
alarm occurrence is detected and power is shut off. 
A circuit breaker (NFB) must be used with the input cables of the power supply. 
 
(1) For 3-phase 200 to 230VAC power supply 
RA
OFF
ON
MC
MC
SK
NFB
MC
L
1
L
2
L
3
L
11
L
21
EMG
SON
SG
VDD
COM
ALM
RA
3-phase
200 to 230 VAC
Forced stop
Servo-on
Trouble
Servo amplifier
Forced
stop