Mitsubishi Electronics MR-J3 ユーザーズマニュアル

ページ / 668
 
 
5 -  7 
5. OPERATION 
 
5.2.5 Point table setting 
Set necessary items to the point table before starting operation. The following table indicates the items that 
must be set. 
 
Name Description 
Position data 
Set the position data for movement. 
Servo motor speed 
Set the command speed of the servo motor for execution of positioning. 
Acceleration time constant 
Set the acceleration time constant. 
Deceleration time constant 
Set the deceleration time constant. 
Dwell 
Set the waiting time when performing automatic continuous operation. 
Auxiliary function 
Set when performing automatic continuous operation. 
 
Refer to section 5.4.2 for details of the point table. 
 
5.2.6 Actual operation 
Start actual operation after confirmation of normal operation by test operation and completion of the 
corresponding parameter settings. Perform a home position return as necessary.