Mitsubishi Electronics MR-J3 ユーザーズマニュアル

ページ / 668
 
 
5 -  29 
5. OPERATION 
 
(4) Timing chart 
100ms
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
0r/min
ON
OFF
ON
OFF
Servo-on (RYn0)
Ready (RD)
Trouble (ALM)
Automatic/manual selection
(RYn6)
Rough match (RXn2)
Servo motor speed
Forward rotation start (RYn1)
Reverse rotation start (RYn2)
Forward rotation jog
Reverse rotation jog
Forward 
rotation
Reverse 
rotation
Movement completion (RXnC)
 
5.5.2 Manual pulse generator 
(1) Setting 
Set the input signal and parameters as follows according to the purpose of use. In this case, the point table 
No. selection 1 to 8 (RYnA to RYnE, RY(n 2)3 to RY(n 2)5) are invalid. 
 
Item Setting 
method 
Description 
Manual operation mode selection 
Automatic/manual selection (RYn6) 
Turn RYn6 OFF. 
Manual pulse generator multiplication 
Parameter No.PA05 
For more information, refer to (3) in 
this section. 
Servo motor rotation direction 
Parameter No.PA14 
Refer to (2) in this section. 
 
(2) Servo motor rotation direction 
 
Servo motor rotation direction 
Parameter No.PA14 setting 
Manual pulse generator: forward rotation 
Manual pulse generator: reverse rotation 
CCW rotation 
CW rotation 
CW rotation 
CCW rotation 
 
CW
CCW
Forward rotation