5. OPERATION 
 
5.6.2 Dog type home position return 
A home position return method using a proximity dog. With deceleration started at the front end of the proximity 
dog, the position where the first Z-phase signal is given past the rear end of the dog or a motion has been 
made over the home position shift distance starting from the Z-phase signal is defined as a home position. 
 
(1) Devices, parameters 
Set the input devices and parameters as follows. 
 
Item Device/Parameter 
used  Description 
Automatic/manual selection (RYn6) 
Turn RYn6 ON. 
Manual home position return mode 
selection 
Point table No. selection 1 to 8  
(RYnA to RYnE, RY(n 2)3 to RY(n 2)5) 
RYnA to RYnE, RY(n 2)3 to RY(n 2)5 
are turned off. 
Remote register-based 
position/speed setting 
(Only when two stations are  
 occupied) 
Position/speed specifying system selection 
(RY(n 2)A) 
Turn RY(n 2)A ON. 
Dog type home position return 
Parameter No.PC02 
0  :Dog type home position return is 
selected. 
Home position return direction 
Parameter No.PC03 
Refer to section 5.6.1 (2) and choose home 
position return direction. 
Dog input polarity 
Parameter No.PD16 
Refer to section 5.6.1 (2) and choose dog 
input polarity. 
Home position return speed 
Parameter No.PC04 
Set speed until detection of dog. 
Creep speed 
Parameter No.PC05 
Set speed after detection of dog. 
Home position shift distance 
Parameter No.PC06 
Set when shifting the home position starting 
at the first Z-phase signal after passage of 
proximity dog rear end. 
Home position return 
acceleration/deceleration time 
constants 
Point table No.1 
Use the acceleration/deceleration time 
constants of point table No.1. 
Home position return position data  Parameter No.PC07 
Set the current position at home position 
return completion. 
 
(2) Length of proximity dog 
To ensure that the Z-phase signal of the servo motor is generated during detection of the proximity dog 
(DOG), the proximity dog should have the length which satisfies formulas (5.1) and (5.2). 
 
L
1
60
V
2
td .............................................................................. (5.1)
 
L
1
  : Proximity dog length [mm] 
: Home position return speed [mm/min] 
td  : Deceleration time [s] 
 
L
2
   2
S.................................................................................... (5.2)
 
 
L
2
  : Proximity dog length [mm] 
S  : Moving distance per servo motor revolution [mm]