Mitsubishi Electronics MR-J3 ユーザーズマニュアル

ページ / 668
 
 
6 -  28 
6. PARAMETERS 
 
6.3.6 Software limit 
A limit stop using a software limit (parameter No.PC31 to PC34) is made as in stroke end operation. When a 
motion goes beyond the setting range, the motor is stopped and servo-locked. This function is made valid at 
power-on but made invalid during home position return. This function is made invalid when the software limit   
setting is the same as the software limit   setting. A parameter error (A37) will occur if the software limit   
setting is less than the software limit   setting. 
Current position
Unmovable
Movable
Movable area
Software limit
Inhibited area