7. MR Configurator 
 
7.5 Point table 
POINT 
 
The value of the parameter No. PA05 set on the parameter setting screen is 
not engaged with the STM (feed length multiplication) value on the point table 
list screen. Set the STM (feed length multiplication) value to the same as set 
in the parameter No. PA05 on the point table list screen. 
 
Click "Point-data" on the menu bar and click "Point table" on the menu. 
 
When the above choices are made, the following window appears. 
e)
c)
a)
b)
h)
d)
g)
f)
 
(1) Point table data write ( a) ) 
Click the point table data changed and press the "Write" button to write the new point table data to the 
servo amplifier. 
 
(2) Point table data verify ( b) ) 
Click the "Verify" button to verify all data being displayed and the data of the servo amplifier. 
 
(3) Point table data batch-read ( c) ) 
Click the "Read All" button to read and display all point table data from the servo amplifier. 
 
(4) Point table data batch-write ( d) ) 
Click the "Write All" button to write all point table data to the servo amplifier.