Mitsubishi Electronics MR-J3 ユーザーズマニュアル

ページ / 668
 
 
7 -  18 
7. MR Configurator 
 
7.7.3 Motor-less operation 
POINT  
When this operation is used in an absolute position detection system, the 
home position cannot be restored properly. 
 
Without a servo motor being connected, the output signals are provided and the servo amplifier display shows 
the status as if a servo motor is actually running in response to the external I/O signals. 
The sequence of the host programmable controller (PC) can be checked without connection of a servo motor. 
 
Click "Test" on the menu bar and click "Operation w/o Motor" on the menu. 
 
When the above choices are made, the following window appears. 
b)
a)
 
(1) Execution of motor-less operation ( a) ) 
Click "Start" to perform motor-less operation. 
 
(2) Termination of motor-less operation ( b) ) 
Click "Close" to close the window. 
Note that just clicking the "Close" button does not cancel motor-less operation. To cancel motor-less 
operation, turn ON the power of the servo amplifier and switch to the CC-Link operation mode once.