Mitsubishi Electronics MR-J3 ユーザーズマニュアル

ページ / 668
 
 
9 -  7 
9. GENERAL GAIN ADJUSTMENT 
 
9.3 Manual mode 1 (simple manual adjustment) 
If you are not satisfied with the adjustment of auto tuning, you can make simple manual adjustment with three 
parameters. 
 
POINT 
 
If machine resonance occurs, filter tuning mode (parameter No.PB01) or 
machine resonance suppression filter (parameter No.PB13 to PB16) may be 
used to suppress machine resonance. (Refer to section 10.1.) 
 
(1) For speed control 
(a) Parameters 
The following parameters are used for gain adjustment. 
 
Parameter No. 
Abbreviation 
Name 
PB06 
GD2 
Ratio of load inertia moment to servo motor inertia moment 
PB07 
PG1 
Model loop gain 
PB09 VG2 
Speed 
loop 
gain 
PB10 VIC 
Speed 
integral 
compensation 
 
(b) Adjustment procedure 
 
Step Operation 
Description 
Brief-adjust with auto tuning. Refer to section 9.2.3. 
 
Change the setting of auto tuning to the manual mode (Parameter 
No.PA08: 0003). 
 
Set an estimated value to the ratio of load inertia moment to servo motor 
inertia moment. (If the estimate value with auto tuning is correct, setting 
change is not required.) 
 
Set a slightly smaller value to the model loop gain 
Set a slightly larger value to the speed integral compensation. 
 
Increase the speed loop gain within the vibration- and unusual noise-free 
range, and return slightly if vibration takes place. 
Increase the speed loop gain. 
Decrease the speed integral compensation within the vibration-free range, 
and return slightly if vibration takes place. 
Decrease the time constant of the speed 
integral compensation. 
Increase the model loop gain, and return slightly if overshooting takes 
place. 
Increase the model loop gain. 
If the gains cannot be increased due to mechanical system resonance or 
the like and the desired response cannot be achieved, response may be 
increased by suppressing resonance with filter tuning mode or machine 
resonance suppression filter and then executing steps 2 and 3. 
Suppression of machine resonance. 
Refer to section 10.2, 10.3. 
While checking the settling characteristic and rotational status, fine-adjust 
each gain. 
Fine adjustment