15 -  29 
15. COMMUNICATION FUNCTION 
 
15.5.6 Disable/enable of I/O devices (DIO) 
Inputs can be disabled independently of the I/O devices ON/OFF. When inputs are disabled, the input signals 
(devices) are recognized as follows. Among the input devices, EMG, LSP and LSN cannot be disabled. 
 
Signal Status 
Input devices (DI) 
OFF 
 
(1) Disabling/enabling the input devices (DI), external analog input signals and pulse train inputs with the 
exception of EMG, LSP and LSN. 
Transmit the following communication commands. 
 
(a) Disable 
 
Command Data 
No. 
Data 
[9][0] [0][0] 
1EA5 
 
(b) Enable 
 
Command Data 
No. 
Data 
[9][0] [1][0] 
1EA5 
 
(2) Disabling/enabling the output devices (DO) 
Transmit the following communication commands. 
 
(a) Disable 
 
Command Data 
No. 
Data 
[9][0] [0][3] 
1EA5 
 
(b) Enable 
 
Command Data 
No. 
Data 
[9][0] [1][3] 
1EA5