Mitsubishi Electronics MR-J3 ユーザーズマニュアル

ページ / 668
 
 
16 -  23 
16. INDEXER POSITIONING OPERATION 
 
16.3 Signal 
16.3.1 Signal (device) explanation 
POINT 
 
In the indexer positioning operation, devices assigned to the CN6 connector 
cannot be changed. 
 
(1) I/O device 
(a) Input device 
 
Device Symbol 
Connector 
pin No. 
Functions/Applications 
Forced stop 
EMG 
CN6-1 
Turn EMG off (open between commons) to bring the motor to an emergency 
stop state, in which the base circuit is shut off and the dynamic brake is 
operated. Turn EMG on (short between commons) in the emergency stop state 
to reset that state. 
Proximity dog 
DOG 
CN6-2 
When DOG is turned OFF, the proximity dog is detected. The polarity of dog 
detection can be changed using parameter No.PD16. 
 
 
 
 
 Parameter 
No.PD16 
Proximity dog (DOG) 
detection polarity 
 
 
 
 
 
0
 (initial value) 
OFF 
 
 
 
 
 
1
 ON 
 
 
 
 
 
Forward rotation stroke end 
LSP 
CN6-3 
Reverse rotation stroke end 
LSN 
CN6-4 
When starting operation, turn LSP/LSN to ON. Turning it to OFF causes a 
sudden stop, resulting in servo lock. A stopping method can be changed in 
parameter No.PD20. 
When not using the forward/reverse rotation stroke end, set "Automatic ON" in 
parameter No.PD01. 
 
  
 
 
(Note) 
Input 
signal 
Operation 
 
 
 
 
 LSP 
LSN 
CCW 
direction 
CW 
direction 
 
  
 
 
 
 
 
  
 
 
 
 
 
  
 
 
 
 
 
  
 
 
 
 
 
 
 
 
 
Note. 0: OFF 
1: ON