Lucent Technologies Release 7 ユーザーズマニュアル

ページ / 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1316
POWER 
9
Notes:
a. Refer to AC-POWER (AC Power) for a description of this test.
b. Refer to CARR-POW for a description of this test.
c. Refer to EMG-XFER (Emergency Transfer) for a description of this test.
d. Refer to CABINET (Cabinet Sensors) for a description of this test.
e. Refer to EXT-DEV (External Alarm) for a description of this test.
f. Refer to RING-GEN (Analog Ring Generator) for a description of this test.
Battery & Battery Charger Query Test (#5)
This test queries the SYSAM in the PPN or the EPN Maintenance circuit pack in 
an EPN for the status of the battery pack and battery charger, and reports the 
result. During this test, the status LED on the battery charger is lit and 
extinguished if the status of the battery charger is reported as normal. This event 
is a result of checking that the battery charger is connected.
Analog Ring Generator Initialization Test (#117) (f)
X
X
ND
Analog Ring Generator Query Test (#118) (f)
X
X
ND
1.
D = Destructive, ND = Non-destructive
Table 9-513.
TEST #5 Battery & Battery Charger Query Test 
Error 
Code
Test 
Result
Description/ Recommendation
1000
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 9-512.
System Technician-Demanded Tests: POWER — Continued
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Continued on next page