Install Management Terminal and Activate System 
Page 3-25
Administer Fiber Links (Release 6r Only) 
3
10. In the 
Line Coding: 
field, enter the line coding information. This 
information should match the line coding of the facility. For T1, example 
line coding is b8zs. For E1, example line coding is hdb3
NOTE:
If this data is not correct, wideband errors (multimedia call handling) 
may occur. 
11. For T1 sites, refer to 
‘‘T1 Installations Only’’
. For E1 sites, refer to 
‘‘E1 
Installations Only’’
.
T1 Installations Only
a. The 
Framing Mode:
 field is display only and shows the hardware setting.
b. The 
DS1CONV-1 Line Compensation:
 and the 
DS1CONV-2 Line 
Compensation:
 fields are display only and show the hardware setting. 
c. In the 
Facility A Circuit ID:
 field, enter an optional facility name 
that is unique to each facility (up to 40 alphanumeric characters). Press 
Enter
.
d. A display similar to the following appears after the fiber link administration 
is completed: 
RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED
.
E1 Installations Only
a. Enter y or n in the 
CRC?
 field. The “CRC” means Cyclic Redundancy 
Check. This is an error detection algorithm.
b. The 
Line Termination:
 field is display only. A 75 (75 Ohms) or 120 
(120 Ohms) typically displays.
c. In the 
Facility A Circuit ID:
 field, enter an optional facility name 
that is unique to each facility (up to 40 alphanumeric characters). Press 
Enter
.
d. A display similar to the following appears after the fiber link administration 
is completed: 
RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED
.