Lucent Technologies Release 6 ユーザーズマニュアル

ページ / 453
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install Management Terminal and Activate System 
Page 3-32
DEFINITY AUDIX Power Procedures 
3
DEFINITY AUDIX Power Procedures
Power Down the AUDIX System
A yellow caution sticker on the system’s power unit notifies technicians to shut 
down the DEFINITY AUDIX System prior to powering down the system.
1. Log into the AUDIX System as craft
2. Enter the reset system shutdown command. Press 
Enter
 
once
.
NOTE:
Do not press 
Enter
 again. This will force the AUDIX to shutdown 
immediately, dropping all active calls on the AUDIX.
3. The “SHUTDOWN Completed” message appears when the AUDIX is 
successfully shutdown. This takes about 2 minutes.
4. The AUDIX System can now be removed for service.
Power Up the AUDIX System
If the AUDIX was removed from the cabinet:
1. Re-install the AUDIX and allow it to boot up automatically.
2. Check for AUDIX System errors.
If the AUDIX remained in the cabinet but power was removed from the 
cabinet:
1. Power up the cabinet. The AUDIX reboots automatically.
2. Check for AUDIX System errors.
If the AUDIX remained in the cabinet and the cabinet was 
not
 powered 
down:
1. At the AUDIX console, hold the 
crtl
 key and enter cc.
2. Enter 5 at the prompt. In about 2 minutes, the AUDIX boots up.
3. When the system initialization is complete, log in as craft.
4. Check for AUDIX System errors.