Page 4-7
Test Duplicated Switch Processing Element Interchange 
4
Test Duplicated Switch Processing
Element Interchange
For high and critical reliability systems only.
1. Verify the screen displays: 
Command:
2. Type status cabinet 1-44 and press 
Enter
.
3. Verify the screen displays test results similar to 
Screen 4-6
.
Screen 4-6.
Example System Status Report for All Cabinets
4. Note the 
MODE
 of 
SPE 1A
 and 
1B
.
5. Type refresh spe
 
and press 
Enter
.
Command successfully completed 
should be displayed.
6. Type reset system interchange
 
and press 
Enter
. This causes the terminal 
to log off.
7. Log in as craft again. Remember to use the new password established for 
craft.
8. Note the 
MODE 
for 
SPE 1A
 and 
1B
 should have changed from that noted 