Lucent Technologies Release 6 ユーザーズマニュアル

ページ / 453
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-10
Auxiliary Connector Outputs 
5
Auxiliary Connector Outputs
The control carrier output cable pinouts are shown in 
Table 5-2
. The control 
carrier AUX connector outputs include the following: 
Alarm monitoring for the auxiliary cabinet.
Seven -48 VDC power sources for emergency transfer units.
Three -48 VDC power sources for remotely powering 3 attendant consoles 
or telephone adjuncts.
The remote management terminal interface trunk connection location.
Access to a relay contact is available to actuate a customer-provided 
light, bell, or similar alarm device. Administer the system to make contact 
when a major, minor or warning alarm condition occurs in the system. The 
circuitry required for this feature is customer-provided. The device 
connected to the alarm leads must not exceed a rating of 30 VAC RMS or 
60 VDC at 0.75 Amps. See 
Table 5-2
 for the pinouts for an external alarm.
A 25-pair connector labeled AUX is provided on the rear of the control carrier. 
Connect a cable to this connector and route to a connecting block on the 
trunk/auxiliary field.
Table 5-2.
Auxiliary Lead Appearances at AUX Connector 
Color 
1,2
Pin Number
AUX Connector Outputs
W-BL
BL-W
26
1
Major
3
W-O
O-W
27
2
Minor
3
W-G
G-W
28
3
GRD
W-BR
BR-W
29
4
GRD
W-S
S-W
30
5
GRD
R-BL
BL-R
31
6
GRD
R-O
O-R
32
7
GRD
R-G
G-R
33
8
Not Connected
R-BR
BR-R
34
9
Not Connected
R-S
S-R
35
10
Not Connected
Continued on next page