Install and Wire Telephones and Other Equipment 
Page 5-44
External Ringing 
5
External Ringing
Connections for external ringing provided by a device, such as a gong, chime, or 
bell, are at an information outlet. The system side of the MDF connects to a 
TN2183 or equivalent analog line circuit pack located in a port carrier. The circuit 
packs contain 16 ports each.
NOTE:
A maximum of 3 devices can connect to 1 TN2183 circuit pack port.
1. Wire the ringing device to the information outlet as shown in 
and 
2. Administer per 
DEFINITY Enterprise Communications Server Release 6 
Administration and Feature Description
.
Queue Warning Indicator
The connections for the queue warning indicator are the same as external 
ringing. An AC indicator (lamp) such as a 21C49 can be used in a Uniform Call 
Distribution/Direct Departmental Calling (UCD/DDC) queue.
The lamp connects to an information outlet. The system side of the MDF 
connects to an analog line circuit pack in a port carrier. 
1. Wire the queue warning indicator to the information outlet as shown in 
2. Administer per 
DEFINITY Enterprise Communications Server Release 6 
Administration and Feature Description
.