Panasonic AK-HRP900P ユーザーズマニュアル
9
Pin No
8
9
10
11
12
13
14
15
Signal
Y signal output
Pb signal output
Pr signal output
Sync signal input
DC 12V
Frame GND
TXD (H)
Signal
Y signal GND
Pb signal GND
Pr signal output
Sync signal GND
DC GND
TXD (C)
RXD (H)
RXD (C)
Pin No
1
2
3
4
5
6
7
CAMERA I / F
MONITOR OUT
G/L IN
TALLY IN
BREAKER
DC 12V IN
Y
P
b
P
r
P/T CONT
M
N
O
P
Q
R
S
_
Rear panel
1
7
2
3
4
5
6
8
9
10
11
12
13
14
15
TXD:
Data from camera to remote controller.
RXD:
Data from remote controller to camera.
N
Swivel stand control signal input connector [P/T CONT (RJ-45)]
Connects the swivel stand control signal output of the pan-tilt control panel (AW-
RP301).
Connects the swivel stand control signal output of the pan-tilt control panel (AW-
RP301).
O
Monitor signal output connector [Y/G, Pb/B, Pr/R] (BNC
k
3)
Outputs the analog signal from the camera.
The output can be changed to R, G, B/Y, Pb, Pr by the camera menu setting.
The output can be changed to R, G, B/Y, Pb, Pr by the camera menu setting.
P
Synch signal input connector [G/L IN] (BNC
k
1)
Inputs the sync signal to the camera. Input 3-value SYNC as the synch signal.
Q
Tally signal input connector [TALLY IN] (2-pin connector block)
Connected to the tally connector from the system. When the HOT connector is at GND
level, the tally LED is lighted.
Connected to the tally connector from the system. When the HOT connector is at GND
level, the tally LED is lighted.
Controls and their Functions
M
Camera connector [CAMERA I/F]
Connected to the camera (AK-HC900P) with the attached cable.
Connected to the camera (AK-HC900P) with the attached cable.