Multiquip CDA45SSIU3 ユーザーズマニュアル

ページ / 78
DCA45SSIU3 50 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #2 (12/19/08) — PAGE 37
*
1
  Replace engine oil and fi lter at 100 hours, fi rst time only.
*
2
  Add “Supplemental Coolant Additives (SCA’S)” to recharge the engine coolant.
*
Replace primary air fi lter element when restriction indicator shows a vacuum of 625 mm (25 in. H20).
*
If blowby hose needs to be replaced, ensure that the slope of the blowby hose is at least a 1/2 inch per foot, 
with no sags or dips that could collect moisture and/or oil. 
Inspection/Maintenance
Table 12. 
10 Hrs 
DAILY
250 Hrs
500 Hrs
1000 
Hrs
Engine
Check Engine Fluid Levels
X
Check Air Cleaner
X
Check Battery Acid Level
X
Check Fan Belt Condition
X
Check for Leaks
X
Check for Loosening of Parts
X
Replace Engine Oil and Filter * 
1
X
Clean Air Filter
X
Check Fuel Filter/Water Separator Bowl
X
Clean Unit, Inside and Outside
X
Change Fuel Filter 
X
Clean Radiator and Check Coolant Protection Level*
2
X
Replace Air Filter Element * 
3
X
Check all Hoses and Clamps * 
4
X
Clean Inside of Fuel Tank
X
Generator
Measure Insulation Resistance Over 3M ohms
X
Check Rotor Rear Support Bearing
X
MAINTENANCE
GENERAL INSPECTION
Prior to each use, the generator should be cleaned and 
inspected for defi ciencies. Check for loose, missing or 
damaged nuts, bolts or other fasteners. Also check for 
fuel, oil, and coolant leaks. Use Table 12 as a general 
maintenance guideline Engine Side (Refer to the Engine 
Instruction Manual)
AIR CLEANER
Every 250 hours: Remove air cleaner element (Figure 52) 
and clean the heavy duty paper element with light spray of 
compressed air. Replace the air cleaner as needed. 
Air Cleaner with Dust Indicator
This indicator (Figure 52) is attached to the air cleaner. 
When the air cleaner element is clogged, air intake 
restriction becomes greater and the dust indicator signal 
shows  RED meaning the element needs changing or 
service. After changing the air element, press the dust 
indicator button to reset the indicator.
Air Cleaner/Indicator
Figure 52. 
NOTICE
The air fi lter should not be changed until the indicator 
reads “RED”. Dispose of old air fi lter. It may not be 
cleaned or reused.