Agilent Technologies 42A ユーザーズマニュアル

ページ / 266
ii
The Oscilloscopes at a Glance 
Choose from a variety of oscilloscopes  for capturing 
long, non-repeating signals
with 200 MSa/s sample rate and 2 MBytes of 
MegaZoom deep memory per channel.
• Agilent 54621A - 2-channel, 60-MHz bandwidth
• Agilent 54621D - 2-channel +16 logic channels, 60-
MHz bandwidth
• Agilent 54622A - 2-channel, 100-MHz bandwidth
• Agilent 54622D - 2-channel +16 logic channels, 
100-MHz bandwidth
• Agilent 54624A - 4-channel, 100-MHz bandwidth
with 2 GSa/s sample rate and 4 MBytes of MegaZoom 
deep memory per channel.
• Agilent 54641A - 2-channel, 350-MHz bandwidth
• Agilent 54641D - 2-channel +16 logic channels, 
350-MHz bandwidth
• Agilent 54642A - 2-channel, 500-MHz bandwidth
• Agilent 54642D - 2-channel +16 logic channels, 
500-MHz bandwidth
Display shows current input signals 
• All analog and digital (54621D/22D/41D/42D) 
channels  displayed in main and delayed mode
• Indicators for channel, time base, digital 
(54621D/22D/41D/42D) channel activity, trigger and 
acquisition status 
• Softkey labels 
• Measurement results 
Digital channel controls select, position, and label 
inputs (54621D/22D/41D/42D)
• Turn channels on or off individually or in groups of 8  
• Rearrange order of channels to group related 
signals  
• Create and display labels to identify channels  
Run control keys begin and end data acquisition 
• Run/Stop starts and stops continuous acquisitions 
• Single performs one acquisition 
• Infinite persistence accumulates and displays the 
results of multiple acquisitions  
General controls measure, save and restore results, 
and configure the oscilloscope 
• Waveform math including FFT, subtract, multiply, 
integrate, and differentiate 
• Use Quick Meas to make automatic measurements 
Integrated counter included with Quick Meas. 
• Use cursors to make manual measurements 
• Save or recall measurement configurations or 
previous results 
• Autoscale performs simple one-button setup of the 
oscilloscope 
Horizontal Controls select sweep speed  and delay 
parameters 
• Sweep speeds from 5 ns/div to 50 ns/div (54620-
series) and 1 ns/div to 50 s/div (54640-series)
• Delay control moves waveform display to point of 
interest 
• Delayed mode and delay allow zooming in to show 
a portion of waveform in detail (split screen) 
Trigger keys define what data the oscilloscope will 
trigger on 
• Source key allows conventional oscilloscope 
triggering
• Modes include Edge, Pulse Width, Pattern, CAN, 
Duration, I
2
C, Sequence, SPI, TV, and USB 
triggering
Softkeys extend the functionality of command keys 
Select measurement types, operating modes, trigger 
specifications, label data, and more 
Digital channel inputs through a flexible probing 
system (54621D/22D/41D/42D)
• Sixteen channels through a dual 8-channel cable 
with micro-clips 
• Set logic levels as TTL, CMOS, ECL, or to a user-
definable voltage
Utilities 
• Dedicated parallel printer port, controller 
operation, floppy disk storage
Built in Quick Help system
• Press and hold any key front-panel key or softkey 
to get help in 11 languages.