Agilent Technologies 42A ユーザーズマニュアル

ページ / 266
3-21
Triggering the Oscilloscope
To use Duration triggering
To use Duration triggering
Duration trigger lets you define a pattern, then trigger on a specified time 
duration of  this logical AND combination of the channels.
1 Press the 
More
 key in the Trigger section of the front panel, rotate the 
Entry knob until 
Duration 
is displayed in the 
Trigger
 softkey, then press 
the 
Settings
 softkey to display the Duration trigger menu.
2 For each analog or digital channel you want to include in the desired 
pattern, press the 
Channel 
softkey to select the channel.
This is the channel source for the H, L, or X condition. As you press the 
Channel 
softkey (or rotate the Entry knob on mixed-signal oscilloscopes), the channel 
you select is highlighted in the 
Pattern =
 line directly above the softkeys and 
in the upper-right corner of the display next to "
Dur
".  External trigger may also 
be specified as a channel in the pattern when using the 2-channel and 4-channel 
oscilloscopes.
Adjust the trigger level for the selected analog channel by turning the Trigger 
Level knob. The position of the trigger level for the analog channel is indicated 
by the trigger level icon 
 at the far left side of the display when DC coupling 
is selected  Set the threshold for the selected digital channel group by pressing 
the 
D7 Thru D0 or D15 Thru D8  key then press the Threshold softkey.  The value 
of the trigger level or digital threshold is displayed in the upper-right corner of 
the display.
Trigger level 
or threshold
Selected 
channel
Duration 
trigger
Channel 
select
Logic level
Return to 
previous menu
Qualifier
Qualifier time set
T